Pengaruh Variasi Udara Pembakaran Terhadap Efisiensi Boiler dengan Menggunakan Perhitungan Metode Langasung dan Tidak Langsung

Authors

  • Restu Dwi Ari Zulfikar Politeknik Negeri Bandung
  • Budi Suharto Politeknik Negeri Bandung
  • Indriyani Indriyani Politeknik Negeri Bandung

DOI:

https://doi.org/10.37859/jst.v11i1.7294
Keywords: Boiler Efficiency, Combustion Air, Direct Method, Indirect Method

Abstract

Boiler type DG1025/17.4 – II 13 Dong Fang Boiler Group Co., Ltd. is a type of boiler is a type of boiler in PLTU Banten 3 Lontar. Boiler efficiency in the steam generation process is influenced by various factors, the most significant of which is how the combustion process occurs in the combustion process occurs in the furnace. Perfect combustin definitely requires a combination of the rught ratio of combustion air and fuel. Based on the result of this researh, it appears that if the actual amount of air flow required for the combustion process is 6.15 kg air/kg coal, then the theoritical air requirements is known to be 8.35 kg air/kg coal. This means that if the actual amount of air flow required for the process is close to the theoritical air flow value, it will indirectly increase the boiler combustion efficiency value. It is proven that when the combustion air variation is the smallest, namely 1050 T/h, it produces a boiler efficiency of 66.82% (direct), then at the largest combustion air variation, namely 1200T/h, it produces an efficiency of 72.40% (direct).

Downloads

Download data is not yet available.

References

American Society of Mechanical Engineers (ASME). (1999). Steam Gemeration Unit, ASME PTC 4.1-1964. New York: ASME.

Boiler Operating Manual Dongfang Boiler Group Co. Ltd.

PLTU 3 Banten (3x315 MW) Maintenance Manual for Boiler Equipment.

Anonim. (2006). PT PLN (Persero). Pusat Pelatihan dan Pendidikan “Teori Pembakaran”.

Babcock & Wilcox, Steam/Its Generation and Use 29ed, The Babcock and Wilcox Co, 1978.