Distribution substation maintenance is an important measure to ensure the continuity of a reliable and safe electricity supply for consumers. This study focuses on the maintenance of cantilever-type distribution substations carried out by PT. PLN (Persero) ULP Anyer in Serang, Banten. This maintenance aims to prevent sudden equipment failures, ensure safety, and enhance the efficiency and durability of the electrical distribution system. The research method employed is qualitative descriptive, involving observation, interviews, and literature review conducted over one month, from July 1 to 31, 2024. The results of the study indicate that the cantilever-type distribution substation at PT. PLN (Persero) ULP Anyer is in good condition, with key components such as transformers, PHB-TR panels, and protective equipment well-maintained and functioning optimally. However, several areas requiring attention were identified, such as the installation of hazard signs and substation numbers to enhance safety and substation identification. Overall, the routine maintenance carried out has proven effective in maintaining the stability and reliability of the electricity distribution system.

Downloads

Download data is not yet available.

Author Biographies

Jahra Damayanti, Universitas Sultan Ageng Tirtayasa

Program Studi S1 Pendidikan Vokasional Teknik Elektro

Mohammad Fatkhurrokhman, Universitas Sultan Ageng Tirtayasa

Program Studi S1 Pendidikan Vokasional Teknik Elektro

References

Drop A, Pada T, Distribusi G, Tegangan J. Analisis drop tegangan pada gardu distribusi jaringan tegangan. J Sains Teknol (AJST). 2024;2(2).

Telaumbanua WM, Bondar R, Napitupulu J. Studi pemeliharaan dan pengoperasian pada gardu distribusi di PT PLN (Persero) ULP Gunungsitoli. J Tek Energi Uda. 2024;13(1):1. https://doi.org/10.46930/jteu.v13i1.4216

Ashari DF. Analisis gangguan gardu distribusi di PT PLN (Persero) ULP Watang Sawitto. Pros Semin Nas Tek Elektro dan Inform. 2021;1(1):2–3.

Poluakan AK, Runtuwene RF, Sambul SAP. Pengaruh kompensasi terhadap kinerja pegawai PT PLN (Persero) UP3 Manado. J Adm Bisnis. 2019;9(2):70. https://doi.org/10.35797/jab.9.2.2019.25114.70-77

Marniati Y. Analisis penambahan jurusan gardu distribusi I.598 pada penyulang Apel PT PLN Rayon Rivai Palembang. J Tekno. 2023;19(2):32–48. https://doi.org/10.33557/jtekno.v19i2.1911

Rizkiana AF, Saputra YM. Perbaikan jatuh tegangan dan rugi daya dengan rekonfigurasi jaringan sambungan rumah dan rekonduktor jaringan tegangan rendah pada gardu distribusi MI-44-150-21 PT PLN ULP Magelang Kota. J List Instrum Elektron Terap. 2024;5(1):1. https://doi.org/10.22146/juliet.v5i1.87020

Damayanti D, Sulistiani H, Umpu EFGS. Sistem pemeliharaan pada jaringan distribusi listrik. J Tek Informasi. 2021;11(1):40–50.

Universitas Bina Jaya, Fakultas Teknik, Prodi Teknik Industri. Optimalisasi sistem distribusi tegangan menengah. J Teknol Ind. 2024;7(1):50–8.

Suparmono A, Harahap R, Cholish, Sembiring M. Studi pemeliharaan komponen utama pada gardu distribusi tipe portal di PT PLN (Persero) Rayon Medan Baru. J Tek Elektro. 2021;4(1):42–7. https://creativecommons.org/licenses/by-sa/4.0/

Rosidin. Upaya meningkatkan kompetensi guru melalui pelatihan penelitian tindakan kelas. Istifkar. 2021;1(1):1–20. https://doi.org/10.62509/ji.v1i1.20

Muharni Y. Perancangan tata letak fasilitas gudang Hot Strip Mill menggunakan metode activity relationship chart dan blocplan. J Tek Ind. 2022;8(1):44. https://doi.org/10.24014/jti.v7i2.11526

Pilendia D. Pemanfaatan Adobe Flash sebagai dasar pengembangan bahan ajar fisika: Studi literatur. J Tunas Pendidik. 2020;2(2):1–10. https://doi.org/10.52060/pgsd.v2i2.255

Shobah MN, Anshory I. Pioneering maintenance strategies for enhanced reliability of low voltage switchboards. Procedia Eng Life Sci. 2024;7:644–50. https://doi.org/10.21070/pels.v7i0.1531

Firmansyah FA, Anshory I. NH fuse maintenance for low voltage network protection. Procedia Eng Life Sci. 2024;7:70–4. https://doi.org/10.21070/pels.v7i0.1583

Wiranto MI, Patras LS, Silimang S. Analisa kinerja transformator distribusi Kawanua Emerald City-Amethyst. Tek Elektro. 2021;2(1):1–11.

Yusa M, Santoso JD. Deteksi dini gangguan pembatas arus listrik pada PHB-TR bertegangan tinggi dengan broadcast SMS Gateway. Pseudocode. 2020;7(2):143–50. https://doi.org/10.33369/pseudocode.7.2.56-63

Hidayati U, Haryanto I, Ismail R. Rancang bangun pendeteksi kecepatan angin berbasis platform IoT Blynk. Rotasi. 2021;23(4):44–9.

Manihuruk J, Simorangkir T, Sitanggang NL. Studi kemampuan arrester untuk pengaman transformator pada gardu induk Tanjung Morawa 150 KV. J Elpotecs. 2021;4(1):16–25. https://doi.org/10.51622/elpotecs.v4i1.447

Yusniati ZP, Armansyah, Taufik I. Pengukuran resistansi isolasi instalasi penerangan basement pada gedung Rumah Sakit Grend Mitra Medika Medan. Bul Utama Tek. 2021;16(3):240–7. https://jurnal.uisu.ac.id/index.php/but/article/download/3788/2644

Fahrezi IA, Liliana. Studi kelayakan pengaman input-output trafo distribusi fuse cut out dan NH fuse di area Payakumbuh. MSI Trans Educ. 2021;2(4).

Downloads

Published

2025-06-30

How to Cite

[1]
J. Damayanti and . M. Fatkhurrokhman, “Pemeliharaan Gardu Distribusi UTCA Tipe Cantol yang dilakukan Oleh PT. PLN Persero ULP Anyer”, JST, vol. 12, no. 1, pp. 246–252, Jun. 2025.

Issue

Section

Research Article