Studi Literatur Tentang Jenis dan Penyebab Gangguan pada Saluran Transmisi
Abstract
Power transmission lines play an important role in distributing electrical energy from power plants to consumers. The reliability of transmission lines is very important to ensure a stable and safe electricity supply. However, various disturbances often occur in transmission lines, both caused by external and internal factors, which can disrupt the operation of the electric power system. This study aims to conduct a literature study on the types of disturbances that occur in transmission lines and identify the causative factors. The method used in this study is a literature study by analyzing various references from books, scientific journals, research reports, and relevant articles. This study identifies several main types of disturbances, such as disturbances due to lightning, strong winds, heavy rain, overload, component failure, and human error. Environmental factors, such as extreme weather and interaction with vegetation, are also common causes of disturbances in transmission lines.
Downloads
References
Waskita F agung. IDENTIFIKASI DAN ANALISIS BLACK OUT AKIBAT GANGGUAN JARINGAN DISTRIBUSI LISTRIK DENGAN MENGGUNAKAN METODE FAULT TREE ANALYSIS (FTA) DAN FAILURE MODE AND EFFECT ANALYSIS (FMEA) (STUDI KASUS: PT. PLN (PERSERO) UNIT PELAKSANAPENGENDALIAN PEMBANGKITAN (UPDK K. AT-TAWASSUTH J Ekon Islam. 2023;VIII(I):1–19.
Dewi A. Studi Analisa Pengaruh Temperatur Dan Tekanan Udara Terhadap Rugi Daya Korona SUTT 150 kV. J Tek Elektro ITP. 2020;9(1):47–53.
Agus Kiswantono AK. Rancang Bangun Proteksi Transmisi Listrik terhadap Multi Gangguan. J Zetroem. 2023;5(2):113–8.
Widyastuti N. Analisis Gangguan Sistem Transmisi Listrik Menggunakan Metode Root Cause Analysis. Ind Eng Online J. 2014;3(3):1–8.
Pangestu A. PENGARUH SAMBARAN PETIR TERHADAP KINERJA RELE JARAK DALAM MENENTUKAN TITIK GANGGUAN PADA SALURAN TRANSMISI. Univ Muhammadiyah Sumatera Utara, Medan. 2020;
Sari M, Asmendri A. Penelitian Kepustakaan (Library Research) dalam Penelitian Pendidikan IPA. Nat Sci. 2020;6(1):41–53.
Handayani M, J.P MJ. Analisa Gangguan Penghantar Berdasarkan Data Rekaman Relai Distance dan Rekaman DFR Bay Penghantar KSRAN-SMKEI 1 di PT PLN ( Persero ) Unit Layanan Transmisi dan Gardu Induk Kisaran Fault Analysis Based on Distance Relay Recording Data and DFR Bay Recordi. 2022;7776.
Napitupulu J, Safarudin I, Hernandez A. Studi Kegagalan Perlindungan Kawat Tanah terhadap Sambaran Petir pada Saluran Transmisi 150 kV. J Teknol Energi Uda. 2021;10(2):60–7.
Syahputra R. Estimasi Lokasi Gangguan Hubung Singkat pada Saluran Transmisi Tenaga Listrik. Semesta Tek. 2015;17(2):106–15.
Seftiani YM, Novizon N, Ari Fitra A. Deteksi Gangguan Saluran Transmisi Menggunakan Metode Gelombang Berjalan dan Transformasi Wavelet Diskrit. Elektron J Ilm. 2023;15(November):43–50.
JURNALIS. SUTT 150 kV Kasongan – Kuala Kurun Beroperasi, PLN Hemat Rp5 Miliar Lebih per Bulan [Internet]. 2023. Available from: https://jurnalis.co.id/2023/08/08/sutt-150-kv-kasongan-kuala-kurun-beroperasi-pln-hemat-rp5-miliar-lebih-per-bulan/
Woso R. PLN UIP Nusra Siap Percepat Pembangunan SUTT 70 kV PLTMG Flores - GI Labuan Bajo [Internet]. 2024. Available from: https://kupang.tribunnews.com/2023/06/05/pln-uip-nusra-siap-percepat-pembangunan-sutt-70-kv-pltmg-flores-gi-labuan-bajo
Yanti FR. Analisa Pengaruh Kontaminan Isolator Terhadap Jumlah Flashover pada Saluran Transmisi 150 kV Koto Panjang-Payakumbuh. Pros Sains Nas dan Teknol. 2022;12(1):559.
Kiswantono A, Permana Putra A. Analisa Perancangan Sistem Transmisi Pembangkit dengan Power150 KVA dan proteksi gangguan listrik di penyaluran 10 KVA menggunakan UPS 8 KVA pada software etap 16.0.0. SinarFe. 2021;565–8.
Reily M. kadata.co.id. 2019. PLN dan ESDM Investigasi Penyebab Listrik Mati Massal di Sebagian Jawa.
Copyright (c) 2024 Nabila Khoirunnisa, Nelli Inayah, Farid Wiherdiansyah, I Kadek Dwi Adyano, Didik Aribowo

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.