Pengaruh Stray Capacitance pada Model Coupling Capacitor Voltage Transformer terhadap Penentuan Lokasi Gangguan Saluran Transmisi 150 kV Menggunakan Metode Transformasi Wavelet Diskrit

Authors

  • Tesya Uldira Septiyeni Institut Teknologi Bisnis Riau
  • Novizon Novizon Universitas Andalas
  • Fanni Sonia Universitas Andalas
  • Rusvaira Qatrunnada Universitas Eka Sakti
  • Mardini Hasanah Akademi Komunitas Olat Maras

DOI:

https://doi.org/10.37859/jst.v13i1.11648
Keywords: Coupling Capacitor Voltage Transformer, Gelombang Berjalan, Sistem Transmisi, Stray Capacitance, Transformasi Wavelet Diskrit

Abstract

Long transmission systems in open areas frequently face challenges in detecting fault locations quickly and accurately. The primary factor behind this inaccuracy stems from the imprecision of the voltage sensor model used. Therefore, this study analyzes the Capacitor Coupling Voltage Transformer (CCVT) model by integrating the effects of stray capacitance. A case study was conducted on the transmission line from the Maninjau Hydroelectric Power Plant (PLTA) to the Pauh Limo Substation (GI). Utilizing the single-ended method assisted by Daubechies 4 wavelet, the simulation results indicate that the CCVT model accounting for stray capacitance yields a lower error rate, resulting in higher accuracy compared to the conventional CCVT model without stray capacitance. Furthermore, the use of a 1 MHz sampling frequency provides higher fault location accuracy than sampling frequencies of 10 kHz and 500 kHz.

Downloads

Download data is not yet available.

References

Greenwood, “Electrical Transients in Power Systems,” IEEE Transactions on Systems, Man and Cybernetics, vol. 3, no. 3. pp. 301-302, 1973. doi: 10.1109/TSMC.1973.4309230

T. U. S. Dkk, “Penggunaan Sensor Tegangan Terhadap Penentuan Lokasi Saluran Gangguan Transmisi 150 kV.pdf,” Surya Tek., vol. 12, no. 2, pp. 370–377, 2025.

S. Kanwal, “Artificial Intelligence Based Faults Identification, Classification, and Localization Techniques in Transmission Lines-A Review.pdf,” IEEE, vol. 21, pp. 1291–2305, 2023.

K. Swain, M. Cherukuri, I. S. Samanta, B. Appasani, N. Bizon, and M. Oproescu, “IoT Based Transmission Line Fault Classification Using Regularized RBF-ELM and Virtual PMU in a Smart Grid,” Comput. Model. Eng. Sci., no. 2, pp. 1993–2015, 2025, doi: 10.32604/cmes.2025.067121.

T. R. Althi and E. Koley, “Fuzzy Logic based Fault Detection and Classification scheme for Series Faults in Six Phase Transmission,” pp. 479–483, 2021.

X. Zhu, S. Li, Y. Guo, X. Chen, C. He, and J. Deng, “Novel wavefront detection and fault location method based on Hilbert-Huang transform for long HVDC transmission lines,” elsevier, vol. 211, no. February, p. 108213, 2022.

R. Gomez, “Study for localization of fault in the electrical distribution systems . Estudio para la localización de fallas en sistemas de distribución eléctrica .,” Ingenius Rev. Cienc. c Tecnol., pp. 64–77, 2023.

Z. Zhu, ; Li Binbin, ; Xue Jianyi, and ; Ding Lijian, “Research on adaptive state prediction method for the metering error of capacitor voltage transformer,” AIP Publ., vol. 94, no. 8, 2023, doi: 10.1016/j.epsr.2006.02.007.

R. L. A. Reis, F. V Lopes, E. P. Ribeiro, C. M. Moraes, K. M. Silva, and A. M. Britto, “Traveling wave-based fault locators : Performance analysis in series-compensated transmission lines,” Elsevier, vol. 223, 2023.

Z. Xiaoguang, H. Chunying, D. Junbo, G. Yubo, and C. Xiaohui, “Research on a Highly Precise Fault Location Method for ± 1 100kV UHVDC Transmission Lines Based on Hilbert-Huang Transform,” pp. 850–854, 2019.

A. Guzmán, B. Kasztenny, Y. Tong, and M. V Mynam, “Accurate and Economical Traveling-Wave Fault Locating Without Communications,” 2018.

C. Xiang, X. Chen, H. Zhao, Z. Ren, and G. Zhao, “Studying the Effect of Stray Capacitance on the Measurement Accuracy of the CVT Based on the Boundary Element Method,” vol. 2021, 2021, doi: 10.1155/2021/1155443.

N. N. Ghuge, S. Jasrotia, and C. Sadhu, “GEIGER MULLER : A THIN END WINDOW TUBE RADIATION DETECTOR,” pp. 190–196, 2015.

S. Wang and G. Xu, “Research on traveling wave fault technology based on ground potential,” no. May, 2023, doi: 10.1063/5.0069963.

S. Poornima, “Frequency Analysis of Gas Discharge Based Memristor Emulator for Ferroresonance,” J. Electr. Syst., pp. 5782–5788, 2024.

Downloads

Published

2026-06-30

How to Cite

[1]
T. U. Septiyeni, N. Novizon, F. Sonia, R. . Qatrunnada, and M. Hasanah, “Pengaruh Stray Capacitance pada Model Coupling Capacitor Voltage Transformer terhadap Penentuan Lokasi Gangguan Saluran Transmisi 150 kV Menggunakan Metode Transformasi Wavelet Diskrit”, JST, vol. 13, no. 1, pp. 296–307, Jun. 2026.

Issue

Section

Research Article

Most read articles by the same author(s)